Caulfield Industrial  are happy to accept items returned to us within 28 days of purchase and in this case we offer you an exchange or a full refund once we receive the items and process them in our warehouse. Any returns which fall outside this 28 day time period may be considered on a case-by-case basis and is at the discretion of Caulfields and may be refunded as a credit against a future purchase. All items must be returned to Caulfields in the same condition in which they were shipped and in a saleable condition. Caulfield Industrial reserves the right to refuse a return if it is determined that the item has been used or worn and then returned for any reason other than being ‘faulty’.

Downloads
Click to view complete product details

Fluke 1736 Three-Phase Energy Logger

 

The Fluke 1736 Three-Phase Power Logger built with Fluke Connect mobile app and desktop software compatibility gives you the data you need to make critical power quality and energy decisions in real-time. The best test tool for conducting energy studies and basic power quality logging, 1736 automatically captures and logs over 500 power quality parameters so you have more visibility into the data you need to optimize system reliability and savings. An optimized user interface, flexible current probes, and an intelligent measurement verification function that allows you to reduce measurement errors by digitally verifying and correcting common connection errors makes setup easier than ever and reduces measurement uncertainty. Access and share data remotely with your team via the Fluke Connect app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits, and check-ins. You can also quickly and easily chart and graph measurements to help identify issues and create detailed reports with the included Fluke Energy Analyze Plus software package.

Features:
  • Presents data locally on the logger or on the Fluke Connect mobile app and desktop software
  • Allows you to power instrument directly from the measured circuit
  • Measures all three phases and neutral with four flexible current probes
  • Allows reviewing measured values during logging sessions and before downloading for real-time analysis
  • Includes event waveform snapshot and high resolution RMS profile, along with date, timestamp and severity to capture dips, swells, and inrush currents and help pinpoint potential root causes of power quality issues
  • Offers a bright, colour, touch-screen display for convenient field analysis and data checks
  • Helps you capture the right data every time with a quick, guided, graphical user interface
  • Reduces uncertainty about your connections with the intelligent verification function
  • Allows you to complete field setups through the front panel or Fluke Connect App on your smartphone
  • Versatile, three-phase Fluke Connect-compatible power logger for conducting basic energy and power quality studies
  • Automatically captures and logs voltage, current, power, harmonics and associated power quality values
  • Automatically logs all measured values and stores more than 20 separate logging sessions
Specifications:
Battery Type Lithium-Ion
Battery Life 4 hours in standard operating mode, up to 5.5 hours in power saving mode
Charging Time less than 6 hours
Voltage Range 100 to 500 volt using safety plug input when powering from the measurement circuit
100 to 240 volt using standard power cord (IEC 60320 C7)
Power Consumption Maximum 50 VA (maximum 15 VA when powered using IEC 60320 input)
Efficiency ≥ 68.2 percent (in accordance with energy efficiency regulations)
Maximum No-Load Consumption < 0.3 watt only when powered using IEC 60320 input
Mains Power Frequency 50/60 Hz ±15 percent
Data Acquisition
Resolution 16-bit Synchronous Sampling
Sampling Frequency 10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input Signal Frequency 50/60 Hz (42.5 to 69 Hz)
Circuit Types 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies)
Data Storage Internal Flash Memory (not user replaceable)
Memory Size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events
Basic Interval
Measured Parameters Voltage, Current, Aux, Frequency, THD V, THD Amps, Power, Power Factor, Fundamental Power, DPF, Energy
Averaging Interval User Selectable: 1, 5, 10, 30 seconds, 1, 5, 10, 15, 30 minutes
Averaging Time Minimum/Maximum Values Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200 ms
Demand Interval (Energy Meter Mode)
Measured Parameters Energy (Wh, varh, VAh), PF, Maximum Demand, Cost of Energy
Interval User selectable: 5, 10, 15, 20, 30 minutes off
Power Quality Measurements
Measured Parameter Voltage, Frequency, Unbalance, Voltage Harmonics, THD V, Current, Harmonics, THD A, TDD
Averaging Interval 10 minutes
Individual Harmonics 2'nd to 50'th Harmonic
Total harmonic Distortion Calculated on 50 harmonics
Events Voltage: Dips, Swells, Interruptions, Current: Inrush Current
Triggered Recordings Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according to IEC61000-4-30)
Waveform of Voltage and Current
Interfaces
USB-A File transfer via USB flash drive, firmware updates
Maximum Current: 120 mA
Wi-Fi File transfer and remote control via direct connection or Wi-Fi infrastructure
Bluetooth Read auxiliary measurement data from Fluke Connect 3000 series modules (requires 1738 or 1736 upgrade option)
USB-Mini Data download device to PC
Voltage Inputs
Number of Inputs 4 (3 phases and neutral)
Maximum Input Voltage 1000 Vrms, CF 1.7
Input Impedance 10 MΩ
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scaling 1:1 and variable
Current Inputs
Number of Inputs 4, mode selected automatically for attached sensor
Input Voltage Clamp Input: 500/50 mVrms; CF 2.8
Rogowski Coil Input 150/15 mVrms at 50 Hz, 180/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Range 1 to 150 Amps/10 to 1500 Amps with thin flexible current probe i17XX-flex1500 12"
3 to 300 Amps/30 to 3000 Amps with thin flexible current probe i17XX-flex3000 24"
6 to 600 Amps/60 to 6000 Amps with thin flexible current probe i17XX-flex6000 36"
40 mA to 4 Amps/0.4 to 40 Amps with 40 Amps clamp i40s-EL
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scaling 1:1 and variable
Auxiliary Inputs
Number of Inputs 2
Input Range 0 to ±10 volt dc, 1reading/s
Scale Factor (available 2014) Format: mx + b (gain and offset) user configurable
Displayed Units (available 2014) User configurable (7 characters, for example, °C, psi, or m/s)
Wireless Connection
Number of Inputs 2
Supported Modules Fluke Connect 3000 series
Acquisition 1 reading
Operating Temperature -10 to +50 degree Celsius
Storage Temperature -20 to 60 degree Celsius, with battery: -20 to 50 degree Celsius
Operating Humidity 10 to 30 degree Celsius, maximum 95 percent RH
30 to 40 degree Celsius, maximum 75 percent RH
40 to 50 degree Celsius, maximum 45 percent RH
Operating Altitude 2000 metre (up to 4000 metre derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage Altitude 12000 metre
Temperature Coefficient 0.1 x accuracy specification/degree Celsius
Colour LCD display 4.3" active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Accuracy
Parameter Range Resolution Intrinsic Accuracy at Reference Conditions (percent of Reading + percent of Full Scale)
Voltage 1000 volt 0.1 volt ±(0.2 percent + 0.01 percent)
Current: Direct Input i17xx-flex 1500 12" 150 Amps 0.1 Amps ±(1 percent + 0.02 percent)
1500 Amps 1 Amps ±(1 percent + 0.02 percent)
i17xx-flex 3000 24" 300 Amps 1 Amps ±(1 percent + 0.03 percent)
3000 Amps 10 Amps ±(1 percent + 0.03 percent)
i17xx-flex 6000 36" 600 Amps 1 Amps ±(1.5 percent + 0.03 percent)
6000 Amps 10 Amps ±(1.5 percent + 0.03 percent)
i40s-EL clamp 4 Amps 1 mA ±(0.7 percent + 0.02 percent)
40 Amps 10 mA ±(0.7 percent + 0.02 percent)
Frequency 42.5 to 69 Hz 0.01 Hz ±(0.1 percent)
Auxillary Input ±10 volt DC 0.1 mV ±(0.2 percent + 0.02 percent)
Voltage Minimum/Maximum 1000 volt 0.1 voolt ±(1 percent + 0.1 percent)
Current minimum/Maximum Defined by accessory Defined by accessory ±(5 percent + 0.2 percent)
THD on Voltage 1000 percent 0.1 percent ±0.5
THD on Current 1000 percent 0.1 percent ±0.5
Voltage Harmonics 2'nd to 50'th 1000 volt 0.1 volt ≥ 10 volt: ±5 percent of reading
< 10 volt: ±0.5 volt
Current Harmonics 2'nd to 50'th Defined by Accessory Defined by Accessory ≥ 3 percent of Current Range: ±5 percent of reading
< 3 percent of current range: ±0.15 percent of range
Unbalance 100 percent 0.1 percent ±0.2
Intrinsic Uncertainty ±(percent of reading + percent of Range)
Parameter Influence Quantity iFlex1500-12 iFlex3000-24 iFlex6000-36 i40S-EL
150/1500 Amps 300/3000 Amps 600/6000 Amps 4/40 Amps
Active Power P PF ≥ 0.99 1.2 percent + 0.005 percent 1.2 percent + 0.0075 percent 1.7 percent + 0.0075 percent 1.2 percent + 0.005 percent
Active Energy Ea PF ≥ 0.99 1.2 percent + 0.005 percent 1.2 percent + 0.0075 percent 1.7 percent + 0.0075 percent 1.2 percent + 0.005 percent
Apparent power S 0 ≤ PF ≤ 1 1.2 percent + 0.005 percent 1.2 percent + 0.0075 percent 1.7 percent + 0.0075 percent 1.2 percent + 0.005 percent
Apparent Energy Eap 0 ≤ PF ≤ 1 1.2 percent + 0.005 percent 1.2 percent + 0.0075 percent 1.7 percent + 0.0075 percent 1.2 percent + 0.005 percent
Reactive power Q 0 ≤ PF ≤ 1 2.5 percent of measured apparent power
Reactive Energy Er 0 ≤ PF ≤ 1 2.5 percent of measured apparent power
Power Factor PF - ±0.025
Displacement Power Factor - ±0.025
DBF/cos? - ±0.025
Additional Uncertainty in percent of Range VP-N>250 volt 0.015 percent 0.0225 percent 0.0225 percent

0.015 percent

Size Instrument: 198 x 167 x 55 mm
Power Supply: 130 x 130 x 45 mm
Instrument with Power Supply Attached: 198 x 167 x 9 mm
Weight Instrument: 1.1 kg
Power Supply: 0.4 kg
Includes:
  • Power Supply
  • Voltage Test Leads
  • Alligator Clips
  • Flexible Current Probe
  • Energy Analysing Software
  • Wi-Fi Adapter
  • Line Cords
  • Colour Coding Set
  • Documentation on USB Flash Drive
  • Soft Carry Case

Technical File:

Close

POP-IN HTML goes here

Close

Your Basket

Your basket is currently empty