Fluke 376 FC True-RMS AC/DC Clamp Meter
Fluke 376 FC True-RMS AC/DC Clamp Meter is available to buy online at Caulfield Industrial. Fluke 376 FC is part of the Fluke Connect family of wireless test tools.
Features:
- Connect your meter to your smartphone with Fluke Connect Measurements
- Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
- Record results directly to your phone and the Cloud
- Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
- Create and share reports from the field via email, or converse in real-time with ShareLive video calls
- iFlex flexible current probe expands the measurement range to 2500 AC; provides access to large conductors in tight spaces
- Integrated VFD low pass filter for accurate motor drive measurements
- Proprietary inrush measurement technology to filter outthe noise and capture motor starting current exactly as the circuit protection sees it
Specifications:
Battery Type |
AA |
Maximum Voltage Between Any Terminal and Earth Ground |
1000 volt |
Operating Temperature |
-10 to 50 degree Celsius |
Storage Temperature |
-40 to 60 degree Celsius |
Operating Humidity - Non-Condensing (< 10 degree Celsius) |
≤90 percent RH (at 10 to 30 degree Celsius) ≤75 percent RH (at 30 to 40 degree Celsius) ≤45 percent RH (at 40 to 50 degree Celsius) |
Operating Altitude |
2000 metre |
Storage Altitude |
12000 metre |
Jaw Opening |
34 mm |
Flexible Current Probe Diameter |
7.5 mm |
Flexible Current Probe Cable Length (Head to Electronics Connector) |
1.8 metre |
AC Current via Jaw |
Range |
999.9 Amps |
Resolution |
0.1 Amps |
Accuracy |
2 percent ±5 digits (10 to 100 Hz) 2.5 percent ±5 digits (100-500 Hz) |
Crest Factor (50/60 Hz) |
3 at 500 Amps 2.5 at 600 Amps Add 2 percent for C.F. >2 |
AC Current via Flexible Current Probe |
Range |
2500 Amps |
Resolution |
0.1 Amps (≤ 600 Amps) 1 Amps (≤ 2500 Amps) |
Accuracy |
3 percent ±5 digits (5 – 500 Hz) |
Crest Factor (50/60Hz) |
3.0 at 1100 Amps 2.5 at 1400 Amps 1.42 at 2500 Amps Add 2 percent for C.F. > 2 |
Position Sensitivity |
|
Distance from Optimum |
|
i2500-10 Flex |
i2500-18 Flex |
Error |
A |
12.7 mm |
35.6 mm |
±0.5 percent |
B |
20.3 mm |
50.8 mm |
±1.0 percent |
C |
35.6 mm |
63.5 mm |
±2.0 percent |
DC Current |
Range |
600 Amps |
Resolution |
0.1 Amps |
Accuracy |
2 percent ±5 digits |
AC Voltage |
Range |
1000 volt |
Resolution |
0.1 volt (≤600.0 volt) 1 volt (≤1000 volt) |
Accuracy |
1.5 percent ±5 digits (20 to 500 Hz) |
DC Voltage |
Range |
1000 volt |
Resolution |
0.1 volt (≤600.0 volt) 1 volt (≤1000 volt) |
Accuracy |
1 percent ±5 digits |
mV dc |
Range |
500.0 mV |
Resolution |
0.1 mV |
Accuracy |
1 percent ±5 digits |
Resistance |
Range |
6000 Ω |
Resolution |
0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) |
Accuracy |
1 percent ±5 digits |
Capacitance |
Range |
1000 μF |
Resolution |
0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
Accuracy |
1 percent ±4 digits |
Size |
249 x 85 x 45 mm |
Weight |
0.395 kg |
Includes:
- 2 x AA Batteries
- Test Leads
- Flexible Current Probe
- Magnetic Hanging Strap
- Coated Instruction Card
- Safety Information Sheet
- Soft Carry Case