Fluke 902 True-RMS HVAC Clamp Meter
The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ, AC current and AC/DC voltage, capacitance, and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight workspaces. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive video calls or email.
Features:
- Ergonomic design fits in your hand and can be used while wearing personal protective equipment
- Large, easy-to-read backlit display improves readings in low light settings
- Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
- Offers True-RMS voltage and current measurements to accurately measure non-linear signals
- Offers Minimum, Maximum recording to capture variations automatically
- A wireless Fluke Connect-enabled clamp meter designed specifically for the needs of HVAC technicians
- Captures flue gas temperature
- Measures start and run motor capacitors
- Measures variable frequency drive performance
Specifications:
Maximum Voltage Between Any Terminal and Earth Ground |
1000 volt |
Battery Type |
AA Alkaline |
Temperature |
Operating: -10 to 50 degree Celsius Storage: -40 to 60 degree Celsius |
Operating Humidity |
Non Condensing (< 10 degree Celsius), ≤90 percent RH (at 10 to 30 degree Celsius), ≤75 percent RH (at 30 to 40 degree Celsius), ≤45 percent RH (at 40 to 50 degree Celsius) |
Altitude |
Operating: 3000 metre Storage: 12000 metre |
Amps AC (via Jaw) |
Resolution |
0.01/0.1 Amps |
Accuracy |
2.0% ±5 digit (45-65 Hz) |
2.5 percent ±5 digit (65-400 Hz) |
Range |
60.00/600.0 Amps |
Crest Factor (50Hz or 60Hz) |
2.5 MIN at 220 Amps 3.0 MIN at 180 Amps > 1.4 MIN at 600 Amps Add 2 percent for CF>400 Amps |
Voltage AC |
Resolution |
0.1 volt |
Accuracy |
1.5 percent ±5 digits |
Range |
600.0 volt |
Voltage DC |
Resolution |
0.1 volt |
Accuracy |
1.5 percent ±5 digits |
Range |
600.0 volt |
Ohms |
Resolution |
0.1/1/10 |
Accuracy |
1 percent ±5 digits |
Range |
600/6000/60.00 kΩ |
Capacitance |
Resolution |
0.1/1 µF |
Accuracy |
1 percent ±4 digits |
Range |
100.0/1000 µF |
µA |
Resolution |
0.1 µA |
Accuracy |
1 percent ±5 digits |
Range |
200 µA |
Contact Temperature |
Resolution |
0.1 C/F |
Accuracy |
1 percent ±8 digits |
Range |
-40 to 400 degree Celsius |
Continuity Beeper |
Beeper Volume |
75 dBA nom. 15 cm. from case front |
On threshold |
<=30 Ω |
Includes:
- 2 x AA Batteries
- Test Leads
- DMM Temperature Probe
- User Manual
- Statement of Calibration
- Soft Carrying Case