Fluke 117 Non-Contact Voltage Electrician's Ideal Multimeter
Designed by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Minimum, Maximum and Average readings, and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.
Features:
- Measures resistance, continuity, frequency, and capacitance
- Provides Min/Max/Average to record signal fluctuations
- Comes with a holster with probe holders for easy storage
- Features compact ergonomic design for one-handed operation
- Fits into optional ToolPak magnetic hanger for hands-free operation
- Safe use in CAT III 600 V environments
- A large white LED backlight to improve measurement visibility in poorly lit areas
- VoltAlert technology for fast, go/no go non-contact voltage detection
- AutoVolt and low input impedance modes to provide faster, more accurate readings
Specifications:
Battery Type |
Alkaline |
Battery Life |
400 hours |
Maximum Voltage Between Any Terminal and Earth Ground |
600 volt |
Operating Temperature |
-10 to 50 degree Celsius |
Storage Temperature |
-40 to 60 degree Celsius |
Display |
Digital: 6000 counts, updates 4 per seconds |
Bar Graph |
33 segments, updates 32 per seconds |
DC Millivolts |
Range/Resolution |
600.0/0.1 mV |
Accuracy |
±([percent of reading] + [counts]): 0.5 percent + 2 |
DC Volts |
Range/Resolution |
6.000/0.001 volt 60.00/0.01 volt 600.00/0.1 volt |
Accuracy |
±([percent of reading] + [counts]): 0.5 percent + 2 |
Auto Volts |
Range/Resolution |
600.0/0.1 volt |
Accuracy |
2.0 percent + 3 (DC, 45 Hz to 500 Hz) 4.0 percent + 3 (500 Hz to 1 kHz) |
AC Millivolts True-RMS |
Range/Resolution |
600.0/0.1 mV |
Accuracy |
1.0 percent + 3 (DC, 45 Hz to 500 Hz) 2.0 percent + 3 (500 Hz to 1 kHz) |
AC Volts True-RMS |
Range/Resolution |
6.000/0.001 volt 60.00/0.01 volt 600.0/0.1 volt |
Accuracy |
1.0 percent + 3 (DC, 45 Hz to 500 Hz) 2.0 percent + 3 (500 Hz to 1 kHz) |
Continuity |
Range/Resolution |
600/1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer |
Ohms |
Range/Resolution |
600.0/0.1 Ω 6.000/0.001 kΩ 60.00/0.01 kΩ 600.0/0.1 kΩ 6.000/0.001 MΩ |
Accuracy |
0.9 percent + 1 |
Range/Resolution |
40.00/0.01 MΩ |
Accuracy |
5 percent + 2 |
Diode Test |
Range/Resolution |
2.00/0.001 volt |
Accuracy |
0.9 percent + 2 |
Capacitance |
Range/resolution |
1000/1 nF 10.00/0.01 μF 100.0/0.1 μF 999/1 μF 100 μF to 1000 μF |
Accuracy |
1.9 percent + 2 |
Range/Resolution |
> 1000 μF |
Accuracy |
5 percent + 20 percent |
Lo-Z Capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10 percent + 2 typical |
AC Amps True-RMS (45 Hz to 500 Hz) |
Range/Resolution |
6.000/0.001 Amps 10.00/0.01 Amps |
Accuracy |
1.5 percent + 3 20 Amps continuous overload for 30 seconds maximum |
DC Amps |
Range/Resolution |
6.000/0.001 Amps, 10.00/0.01 Amps
|
Accuracy |
1.0 percent + 3 20 Amps continuous overload for 30 seconds maximum |
Frequency (Volt or Amps Input) |
Range/Resolution |
99.99/0.01 Hz 999.99/0.1 Hz 9.999/0.001 Hz 50.00/0.01 Hz |
Accuracy |
0.1 percent + 2 |
Weight |
0.55 kg |
Includes:
- Silicone Test Lead Set
- Holster
- User Manual