Fluke 1777 Three-Phase Power Quality Analyzer
The Fluke 434 II is designed for users who need to get to the solution of the power quality problem as quickly as possible so that they can minimize expensive downtime. The measurement process and display of data is optimized to get to the most important information as quickly as possible. Multiple parameters are measured simultaneously and displayed in formats that quickly describe overall power quality health while giving you the detailed information you need to make better maintenance decisions. Data can be quickly accessed as simple digital values, trend graphs that give you fast insight into changes over time, waveforms, phasor diagrams or analyzed and organized into a tabular format such as the event data where the magnitude, duration, and time stamping enable rapid correlation to the problems you are experiencing in your facility.
Features:
- Automatically measure power and power quality parameters
- Power system connection and instrument setup autocorrection
- Instrument automatically detects error in voltage and current wiring, providing correction without rewiring
- High resolution touchscreen
- Capacitive touchscreen allows use with PPE (double gloved hands), providing clear results in seconds
- Power quality health summary: automatically evaluate power quality inputs against the EN 50160 electrical standard, providing detailed troubleshooting of power quality problem areas
- Harmonics: multiple methods of harmonic analysis provide users with the data they increasingly need with basic fundamental to 50 integer harmonics, 2 to 9 kHz for IEC61000-4-30 Annex A compliance and harmonics to 30 kHz harmonics to discover the effects of inverters on the network
- Critical power quality data is captured as soon as you begin a session, without extensive setup or selections
- Intuitive user interface makes it easy to navigate between measurement parameters like V/A/Hz, power, dips and swells, harmonics, or PQ health at the push of a button
- Capture damaging high-speed transients so you can mitigate their effects before equipment fails
- Analysis and reporting comes standard with Fluke Energy Analyze Plus software giving you the ability to create customized reports, or leverage built-in one-click reporting to industry standards like EN 50160, IEEE 519 and GOST 33073
Specifications:
Number of Inputs | 4 inputs, 3 phases and neutral referenced to PE (5 connectors) |
Measurement Category | 1000 V CAT III/600 V CAT IV |
Maximum Input Voltage | 1000 V rms/1000 V DC (1700 Vpk) |
Nominal Voltage Range | Wye and single phase: variable (50 to 1000 V) Delta: variable (100 to 1000 V) IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 to 690 V |
Input Impedance | 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE |
Bandwidth | DC to 30 kHz for PQ measurements, excluding transients |
Resolution | 24-bit synchronous sampling |
Sampling Frequency | 80 kS/second at 50/60 Hz |
Scaling | 1:1 variable for use of potential transformers |
Includes:
- Power Quality Analyzer
- Current Probes
- WIFI/BLE Module
- Voltage Test Lead
- 2 x Alligator Clips
- USB-C Cable
- Line Cord
- Test Lead Set
- Magnet Probe Set
- Magnetic Hanging Kit
- Cable Marker Set
- Wall Outlet Adaptor
- Hard Case
- Statement of Calibration Practices
Each unit is customizable, please contact Our Sales Department for more details on the options available Tel: 091-795000