Battery Type |
AA Alkaline |
Battery Life |
250 hours Minimum |
RF Communication Range |
Open Air, Unobstructed |
Up to 20 metre |
Obstructed, Sheetrock Wall |
Up to 6.5 metre |
Obstructed, concrete wall, or steel electrical enclosure |
Up to 3.5 metre |
Temperature |
Operating |
-10 to 50 degree Celsius |
Storage |
-40 to 60 degree Celsius |
Temperature Co-efficient |
0.1 X (Specified Accuracy)/degree Celsius (< 18 degree Celsius or > 28 degree Celsius) |
Relative Humidity |
0 to 90 percent (0 to 35 degree Celsius) 0 to 75 percent (35 to 40 degree Celsius) 0 to 45 percent (40 to 50 degree Celsius) |
Altitude |
Operating |
2000 metre |
Storage |
12000 metre |
Maximum Voltage between Any Terminal and Earth Ground |
1000 V DC or AC RMS |
Ω Fuse Protection From A Inputs |
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
Display (LCD) |
Update Rate |
4 per seconds |
Volts, Amps, Ohms |
6000 counts |
Frequency |
10000 counts |
Capacitance |
1000 counts |
AC Voltage |
Range/Resolution |
|
600.0/0.1 mV 6.000/0.001 volt 60.00/0.01 volt 600.0/0.1 volt 1000/1 volt |
Accuracy |
45 Hz to 500 Hz |
1.0 percent + 3 |
500 Hz to 1 kHz |
2.0 percent + 3 |
DC Voltage, Continuity, Resistance, Diode Test and Capacitance |
mV |
Range/Resolution |
600.0/0.1 mV |
Accuracy |
0.09 percent + 2 |
V |
Range/Resolution |
6.000/0.001 volt 60.00/0.01 volt 600.0/0.1 volt 1000/ 1 volt |
Accuracy |
0.09 percent + 2 0.15 percent + 2 |
))) |
Range/Resolution |
600/1 Ω |
Accuracy |
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer |
Ω |
Range/Resolution |
600.0/0.1 Ω 6.000/0.001 kΩ 60.00/0.01 kΩ 60.00/0.1 kΩ 600.0/0.001 MΩ 50.00/0.01 MΩ |
Accuracy |
0.5 percent + 2 0.5 percent + 1 1.5 percent + 3 |
Diode Test |
Range/Resolution |
2.000/0.001 volt |
Accuracy |
1 percent + 2 |
µF |
Range/Resolution |
1000/1 nF 10.00/0.01 μF 100.0/0.1 μF 9999/1 μF |
Accuracy |
1.2 percent + 2 10 percen typical |
AC and DC Current |
mA AC (45 Hz to 1 kHz) |
Range/Resolution |
60.00/0.01 mA 400.0/0.1 mA |
Accuracy |
1.5 percent + 3 |
mA DC |
Range/Resolution |
60.00/0.01 mA 400.0 mA/0.1 mA |
Accuracy |
0.5 percent + 3 |
Frequency |
Range/Resolution |
99.99/0.01 Hz 999.9/0.1 Hz 9.999/0.001 kHz 99.99/0.01 kHz |
Accuracy |
0.1 percent + 1 |
Input Characteristics |
|
Overload protection |
1100 volt RMS |
Input impedance (Nominal) |
> 10 MΩ < 100 pF |
Common Mode Rejection Ratio (1 kΩ unbalance) |
> 120 dB at DC, 50 Hz or 60 Hz |
Normal Mode Rejection |
> 60 dB at 50 Hz or 60 Hz |
|
Overload protection |
1100 volt RMS |
Input Impedance (Nominal) |
> 10 MΩ < 100 pF |
Common Mode Rejection Ratio (1 kΩ unbalance) |
> 60 dB, DC to 60 Hz |
Normal Mode Rejection |
> 60 dB at 50 Hz or 60 Hz |
|
Overload Protection |
1100 volt RMS |
Input Impedance (Nominal) |
< 2.7 volt DC |
Full Scale Voltage to 6 MΩ Full Scale Voltage 50 MΩ |
< 0.7 volt DC < 0.9 volt DC |
Typical Short Circuit Current |
< 350 mA |