Battery Type |
AA |
Battery Life (With Typical Usage, backlight off) |
100 hours |
Operating Temperature |
0 to 50 degree Celsius |
Storage Temperature |
-20 to 60 degree Celsius |
Operating Humidity |
0 to 95 percent (Non-Condensing) |
Operating Altitude |
2000 metre |
Storage Altitude |
10000 metre |
Drop Test Requirements |
1 metre |
Temperature Coefficients |
Current |
0.1 percent of reading per degree Celsius outside 22 to 24 degree Celsius |
Voltage |
0.1 percent of reading per degree Celsius outside 22 to 24 degree Celsius |
Test Leads |
Rated to 1000 volt |
Jaw Size |
58 mm |
Current Measurement DC and AC 10 to 100 Hz |
Range |
40/400/2000 Amps, 1400 AC RMS |
Resolution |
10 mA/100 mA/ 1 Amps |
Accuracy |
A: 1.5 percent rdg + 15 digits A: 1.5 percent rdg + 5 digits |
Trigger Level for Inrush |
0.50/5.0/5 Amps |
Trigger Level for Hz Filter Off |
2.50/2.5/8 Amps |
Trigger Level for Hz Filter On |
0.50/2.5/8 Amps |
Crest Factor (50/60 Hz) |
Range |
40/400/2000 Amps, 1400 AC RMS |
Crest Factor |
2 at 33 Amps, 2.4 at 27 Amps 2 at 330 Amps, 2.4 at 270 Amps 2 at 1000 Amps, 2.4 at 833 Amps |
Current Measurement AC 100.1 Hz to 1 kHz |
Range |
40/400/2000 Amps, 1400 AC RMS |
Resolution |
10/100 mA/1 Amps |
Accuracy |
10 A: 3.5 percent rdg + 15 digits 10 A: 3.5 percent rdg + 5 digits |
Trigger Level for Inrush |
0.50/5.0/5 Amps |
Trigger Level for Hz Filter Off |
2.50/2.5/8 Amps |
Trigger Level for Hz Filter On |
0.50/2.5/8 Amps |
Voltage Measurement DC and AC 10 Hz to 100 Hz (600 volt and 1000 volt ranges have 10 percent over range to 660 volt and 1100 volt respectively) |
Range |
4/40/400/600 volt AC rms/1000 VDC |
Resolution |
1/10/100mV/ 1 volt |
Accuracy |
1 percent rdg + 10 digits 1 percent rdg + 5 digits |
Trigger Level for Hz Filter Off |
0.25/6 volt |
Trigger Level for Hz Filter On |
0.25/6 volt |
Voltage Measurement AC 100.1 Hz to 1 kHz (600 volt and 1000 volt ranges have 10 percent over range to 660 volt and 1100 volt respectively) |
Range |
4/40/400/600 volt AC RMS |
Resolution |
1/10/100/1 volt |
Accuracy |
3 percent rdg + 10 digits 3 percent rdg + 5 digits |
Trigger Level for Hz Filter Off |
0.050/0.25/ 6 volt |
Trigger Level for Hz Filter On |
0.050/0.25/6 volt |
Ohms Measurement |
Range |
4/40/400 kΩ |
Resolution |
0.1/1/10/100 Ω |
Accuracy |
1.5 percent + 5 digits |
Continuity Beeper |
On at ≤ 30 Ω Off at ≥ 100 Ω |
Frequency Measurement |
Measurement Range |
5.0 Hz to 1 kHz |
Resolution |
0.1 Hz (15 to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) |
Accuracy – 5.0 Hz to 100 Hz |
0.2 percent + 2 counts |
Accuracy – 100.1 Hz to 1 kHz |
0.5 percent + 5 counts |
Trigger Level |
Refer to Current and Voltage Tables |
Size |
300 x 98 x 52 mm |
Weight |
0.814 kg |