Fluke 374FC True-RMS AC/DC Clamp Meter
The Fluke 374, part of the Fluke Connect family of wireless test tools, delivers the standard features you need for everyday troubleshooting. Measure AC and DC current to 600 Amps with the fixed jaw clamp or add an optional iFlex flexible current probe to measure all the way to 2500 Amps. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access tightly packed wires. You can also use the 374 FC to measure AC and DC voltage to 1000 volt and resistance to 6000 Ω.
The 374 is Fluke Connect-enabled to wirelessly transmit results via Bluetooth to Apple and Android devices. That means you can read the results out of the arc flash zone, wearing less PPE. You can even save results to the cloud and create and send reports in email right from the field. Or converse in real-time with ShareLive video calls. With True-RMS AC voltage and current measurements, the 374 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 374 Clamp Meter is the direct replacement for the Fluke 374 Clamp Meter.
Features:
- Compatible with optional TPAK magnetic hanging strap
- Provides True-RMS voltage and current measurements to accurately measure non-linear signals
- Advanced clamp meter that transmits measurements to your smartphone via Fluke Connect for viewing at a safer distance
- Measures AC current to 2500 Amps AC with the optional iFlex flexible current probe
Specifications:
Battery Type |
AA |
Maximum Voltage Between Any Terminal and Earth Ground |
1000 volt |
Operating Temperature |
-10 to 50 degree Celsius |
Storage Temperature |
-40 to 60 degree Celsius |
Operating Humidity - Non-Condensing (< 10 degree Celsius) |
≤90 percent RH (at 10 to 30 degree Celsius) ≤75 percent RH (at 30 to 40 degree Celsius) ≤45 percent RH (at 40 to 50 degree Celsius) |
Operating Altitude |
3000 metre |
Storage Altitude |
12000 metre |
Jaw Opening |
34 mm |
Flexible Current Probe Diameter |
7.5 mm |
Flexible Current probe Cable Length (Head to Electronics Connector) |
1.8 metre |
AC Current via Jaw |
Range |
600 Amps |
Resolution |
0.1 Amps |
Accuracy |
2 percent ±5 digits (10 to 100 Hz) 2.5 percent ±5 digits (100-500 Hz) |
Crest Factor (50/60 Hz) |
2.5 at 600 Amps Add 2 percent for C.F. >2 |
AC Current via Flexible Current Probe |
Range |
2500 Amps |
Resolution |
0.1 Amps (≤ 600 Amps) 1 Amps (≤ 2500 Amps) |
Accuracy |
3 percent ±5 digits (5 – 500 Hz) |
Crest Factor (50/60Hz) |
2.5 at 1400 Amps 1.42 at 2500 Amps Add 2 percent for C.F. > 2 |
Position Sensitivity |
|
Distance from Optimum |
|
i2500-10 Flex |
i2500-18 Flex |
Error |
A |
12.7 mm |
35.6 mm |
±0.5 percent |
B |
20.3 mm |
50.8 mm |
±1.0 percent |
C |
35.6 mm |
63.5 mm |
±2.0 percent |
DC Current |
Range |
600 Amps |
Resolution |
0.1 Amps |
Accuracy |
2 percent ±5 digits |
AC Voltage |
Range |
1000 volt |
Resolution |
0.1 volt (≤600.0 volt) 1 volt (≤1000 volt) |
Accuracy |
1.5% ±5 digits (20 to 500 Hz) |
DC Voltage |
Range |
1000 volt |
Resolution |
0.1 volt (≤600.0 volt) 1 volt (≤1000 volt) |
Accuracy |
1 percent ±5 digits |
mV dc |
Range |
500.0 mV |
Resolution |
0.1 mV |
Accuracy |
1 percent ±5 digits |
Resistance |
Range |
6000 Ω |
Resolution |
0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) |
Accuracy |
1 percent ±5 digits |
Capacitance |
Range |
1000 μF |
Resolution |
0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
Accuracy |
1 percent ±4 digits |
Size |
249 x 85 x 45 mm |
Weight |
0.395 kg |
Includes:
- 2 x AA Batteries
- Test Leads
- Coated Instruction Card
- Safety Information Sheet
- Soft Carry Case