Fluke 375 True-RMS AC/DC Clamp Meter
The Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high-performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect. The 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlex probe in the package. You can measure AC and DC current to 600 Amps and voltage up to 1000 volt with the fixed jaw clamp. Or connect an optional iFlex flexible current probe to expand your measurement range to 2500 Amps AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires.
Features:
- Compatible with optional TPAK magnetic hanging strap
- Includes True-RMS voltage and current measurements to accurately measure non-linear signals
- Measures frequency and resistance to 60 k? with continuity detection
- Includes Minimum, Maximum and Average and inrush recording to capture variations automatically
- Offers 500 mV DC measurement range to interface with other accessories
- High-performance clamp meter that measures very low voltage and high resistance
- Transmits measurements to your smartphone via Fluke Connect so you can view them at a safer distance
Specifications:
Battery Type |
AA |
Maximum Voltage Between Any Terminal and Earth Ground |
1000 volt |
Operating Temperature |
-10 to 50 degree Celsius |
Storage Temperature |
-40 to 60 degree Celsius |
Operating Humidity - Non-Condensing (< 10 degree Celsius) |
≤90 percent RH (at 10 to 30 degree Celsius) ≤75 percent RH (at 30 to 40 degree Celsius) ≤45 percent RH (at 40 to 50 degree Celsius) |
Operating Altitude |
3000 metre |
Storage Altitude |
12000 metre |
Jaw Opening |
34 mm |
Flexible Current Probe Diameter |
7.5 mm |
Flexible Current Probe Cable Length (Head to Electronics Connector) |
1.8 metre |
AC Current via Jaw |
Range |
600 Amps |
Resolution |
0.1 Amps |
Accuracy |
2 percent ±5 digits (10 to 100 Hz) 2.5 percent ±5 digits (100-500 Hz) |
Crest Factor (50/60 Hz) |
3 at 500 Amps 2.5 at 500 Amps Add 2 percent for C.F. >2 |
AC Current via Flexible Current Probe |
Range |
2500 Amps |
Resolution |
0.1 Amps (≤ 600 Amps) 1 Amps (≤ 2500 Amps) |
Accuracy |
3 percent ±5 digits (5 – 500 Hz) |
Crest Factor (50/60Hz) |
3.0 at 1100 Amps 2.5 at 1400 Amps 1.42 at 2500 Amps Add 2 percent for C.F. > 2 |
Position Sensitivity |
|
Distance from Optimum |
|
i2500-10 Flex |
i2500-18 Flex |
Error |
A |
12.7 mm |
35.6 mm |
±0.5 percent |
B |
20.3 mm |
50.8 mm |
±1.0 percent |
C |
35.6 mm |
63.5 mm |
±2.0 percent |
DC Current |
Range |
600 Amps |
Resolution |
0.1 Amps |
Accuracy |
2 percent ±5 digits |
AC Voltage |
Range |
1000 volt |
Resolution |
0.1 volt (≤600.0 volt) 1 volt (≤1000 volt) |
Accuracy |
1.5 percent ±5 digits (20 to 500 Hz) |
DC Voltage |
Range |
1000 volt |
Resolution |
0.1 volt (≤600.0 volt) 1 volt (≤1000 volt) |
Accuracy |
1 percent ±5 digits |
mV dc |
Range |
500.0 mV |
Resolution |
0.1 mV |
Accuracy |
1 percent ±5 digits |
Resistance |
Range |
6000 Ω |
Resolution |
0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) |
Accuracy |
1 percent ±5 digits |
Capacitance |
Range |
1000 μF |
Resolution |
0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
Accuracy |
1 percent ±4 digits |
Size |
249 x 85 x 45 mm |
Weight |
0.395 kg |
Includes:
- 2 x AA Batteries
- Test Leads
- Coated Instruction Card
- Safety Information Sheet
- Soft Carry Case